FDA Device recall Z-1014-2022
ACL TOP 300 CTS/350 CTS/500 CTS/550 CTS/970 CL: Name Part Number 1.ACL TOP 300 CTS 00000280060 2. ACL TOP 300 CTS 00000280060R (Refurbished…
- FDA Device
- Class II
- ongoing
- Published 2022-05-04
On 2022-05-04 the FDA classified a Class II recall of ACL TOP 300 CTS/350 CTS/500 CTS/550 CTS/970 CL: Name Part Number 1.ACL TOP 300 CTS 00000280060 2. ACL TOP 300 CTS 00000280060R (Refurbished… by Instrumentation Laboratory, citing updated and revised user instructions issued 7/14/22. Potential carryover issue may cause elevated quality control and sample results for heparin, apixaban or rivaroxaban when Hem….
Read the official FDA Device notice
| Agency | FDA Device |
|---|---|
| Recall number | Z-1014-2022 |
| Classification | Class II |
| Status | ongoing |
| Initiated | 2022-02-22 |
| Published | 2022-05-04 |
| Last updated | 2026-09-13 11:56 UTC |
| Company | Instrumentation Laboratory |
| Distribution | US |
Product
ACL TOP 300 CTS/350 CTS/500 CTS/550 CTS/970 CL: Name Part Number 1.ACL TOP 300 CTS 00000280060 2. ACL TOP 300 CTS 00000280060R (Refurbished) 3. ACL TOP 350 CTS 00000280065 4. ACL TOP 500 CTS 00000280040 5. ACL TOP 500 CTS 00000280040R ( Refurbished) 6/ 6. ACL TOP 550 CTS 00000280045 7. ACL TOP 970 CL 00000280097
Reason
Updated and revised user instructions issued 7/14/22. Potential carryover issue may cause elevated quality control and sample results for heparin, apixaban or rivaroxaban when HemosIL Liquid Anti-Xa reagent is used in the same run with both HemosIL Liquid Antithrombin and HemosIL Q.F.A. Thrombin (Bovine), specific to instrument models that utilize a single reagent probe
Identifiers
| code_info | All Serial Numbers. Trade Name Part Number UDI ACL TOP 300 CTS 00000280060 08426950556916;…All Serial Numbers. Trade Name Part Number UDI ACL TOP 300 CTS 00000280060 08426950556916; "ACL TOP 300 CTS (Refurbished)" 00000280060R 08426950928027; ACL TOP 350 CTS 00000280065 08426950784081; ACL TOP 500 CTS 00000280040 08426950453499; "ACL TOP 500 CTS (Refurbished)" 00000280040R 08426950928003; ACL TOP 550 CTS 00000280045 08426950729242; ACL TOP 970 CL 00000280097 08430793045476. |
|---|
Status history
No status changes recorded since RecallRadar first saw this recall on 2026-09-13 11:56 UTC. Current status: ongoing.
Other recalls by Instrumentation Laboratory
- HemoslL AcuStar HIT-lgG(PF-4)
FDA Device · Class I · 2026-10-21 · Instrumentation Laboratory - HemoslL AcuStar HIT-lgG(PF-4)
FDA Device · Class I · 2026-10-21 · Instrumentation Laboratory - GEM Premier 5000 PAK Part Numbers: 00055360010 00055360011 00055407504 00055415010 00055430010 00055430011 00055445010 00055445011 00055360…
FDA Device · Class II · 2026-08-12 · Instrumentation Laboratory - GEM Premier 7000 with iQM3 Part Numbers: 00077407508 00077407510 00077415004 00077415008 00077415010 00077430010 Product Description: The G…
FDA Device · Class II · 2026-08-12 · Instrumentation Laboratory - Brand Name: GEM Premier 5000 Product Name: GEM Premier 5000 Model/Catalog Number: 00024019255 Portable blood analyzer system
FDA Device · Class II · 2026-08-05 · Instrumentation Laboratory
All Instrumentation Laboratory recalls
Source
Official record: https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-1014-2022%22
RecallRadar indexes public recall notices from the FDA, USDA FSIS, and CPSC. The official agency notice is the authoritative source. Always confirm details at the linked source before acting.