FDA Device recall Z-2574-2021
NAMIC Manifolds. (1) NAMIC Angiographic MANIFOLD, Medium Pressure, REF 64038301, UPN H965640383011, 3 Valve Manifold, Off Star Handles, Por…
- FDA Device
- Class II
- terminated
- Published 2021-10-06
On 2021-10-06 the FDA classified a Class II recall of NAMIC Manifolds. (1) NAMIC Angiographic MANIFOLD, Medium Pressure, REF 64038301, UPN H965640383011, 3 Valve Manifold, Off Star Handles, Por… by Medline Industries, citing potential for sterile barrier breach. Microscopic pinholes within the sterile pouch could potentially lead to non-sterile conditions.
Read the official FDA Device notice
| Agency | FDA Device |
|---|---|
| Recall number | Z-2574-2021 |
| Classification | Class II |
| Status | terminated |
| Initiated | 2021-08-06 |
| Published | 2021-10-06 |
| Last updated | 2026-09-13 11:56 UTC |
| Company | Medline Industries |
| Distribution | US |
Product
NAMIC Manifolds. (1) NAMIC Angiographic MANIFOLD, Medium Pressure, REF 64038301, UPN H965640383011, 3 Valve Manifold, Off Star Handles, Ports on Right, Rx only, Sterile; (2) NAMIC Angiographic MANIFOLD, Medium Pressure, REF 64038303, UPN H965640383031, 3 Valve Manifold, On Star Handles, Ports on Right, Rx only, Sterile; (3) NAMIC Angiographic MANIFOLD High Pressure, REF 70037200, UPN H965700372001, 2 Valve Manifold, Off Handles, Ports on Right, Rx only, Sterile; (4) NAMIC Angiographic MANIFOLD, High Pressure, REF 70037202, UPN H965700372021, 2 Valve Manifold, On Handles, Ports on Right, Rx only, Sterile. (5) NAMIC Angiographic MANIFOLD, High Pressure, REF 70037301, UPN H965700373011, 3 Valve Manifold, Off Handles, Ports on Right, Rx only, Sterile; (6) NAMIC Angiographic MANIFOLD, High Pressure, REF 70037303, UPN H965700373031, 3 Valve Manifold, On Handles, Ports on Right, Rx only, Sterile; (7) NAMIC Angiographic MANIFOLD, Medium Pressure, REF 70038200, UPN H965700382001, 2 Valve Manifold, Off Handles, Ports on Right, Rx only, Sterile; (8) NAMIC Angiographic MANIFOLD, Medium Pressure, REF 70038202, UPN H965700382021, 2 Valve Manifold, On Handles, Ports on Right, Rx only, Sterile; (9) NAMIC Angiographic MANIFOLD, Medium Pressure, REF 70038301, UPN H965700383011, 3 Valve Manifold, Off Handles, Ports on Right, Rx only, Sterile; (10) NAMIC Angiographic MANIFOLD, Medium Pressure, REF 70038303, UPN H96570038301, 3 Valve Manifold, On Handles, Ports on Right, Rx only, Sterile; (11) NAMIC Angiographic MANIFOLD, Medium Pressure, REF 70039202, UPN H965700392021, 2 Valve Manifold, On Handles, Ports on Right, Rx only, Sterile; (12) NAMIC Angiographic MANIFOLD, Medium Pressure, REF 70039301, UPN H965700393011, 3 Valve Manifold, Off Handles, Ports on Right, Rx only, Sterile; and (13) NAMIC Angiographic MANIFOLD, Medium Pressure, REF 70039303, 3 Valve Manifold, On Handles, Ports on Right, Rx only, Sterile.
Reason
Potential for sterile barrier breach. Microscopic pinholes within the sterile pouch could potentially lead to non-sterile conditions.
Identifiers
| code_info | Expiration dates 12/31/2023-6/30/2024. (1) REF 64038301 - Lot numbers 0000006342, 0000008482, 0000016519; UPN H965640…Expiration dates 12/31/2023-6/30/2024. (1) REF 64038301 - Lot numbers 0000006342, 0000008482, 0000016519; UPN H965640383011 - Lot number 5642413; (2) REF 64038303 - Lot numbers 0000010144, 0000014189, 0000016524; UPN H965640383031 - Lot number 5642416; (3) REF 70037200 - Lot numbers 0000002033, 0000008570, 0000016521; UPN H965700372001 - Lot numbers 5649219, 5659335; (4) REF 70037202 - Lot numbers 0000014365, 0000016522; UPN H965700372021 - Lot numbers 5642417, 5642565, 5642566, 5642567, 5642568, 5643626, 5647596; (5) REF 70037301 - Lot numbers 0000002024, 0000006320, 0000010129; UPN H965700373011 - Lot number 5662011; (6) REF 70037303 - Lot numbers 0000002051, 0000006046; UPN H965700373031 - Lot numbers 5655475, 5662957, 5664026; (7) REF 70038200 - Lot numbers 0000001974, 0000006032, 0000010140, 0000014125; UPN H965700382001 - Lot numbers 5645162, 5649221, 5662013; (8) REF 70038202 - Lot numbers 0000007917, 0000010149, 0000016523; UPN H965700382021 - Lot numbers 5642414, |
|---|
Status history
No status changes recorded since RecallRadar first saw this recall on 2026-09-13 11:56 UTC. Current status: terminated.
Source
Official record: https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-2574-2021%22
RecallRadar indexes public recall notices from the FDA, USDA FSIS, and CPSC. The official agency notice is the authoritative source. Always confirm details at the linked source before acting.