FDA Device recall Z-2496-2018
Ingenuity Digital PET/CT System, Model 882446 with the following UDI's: (01)00884838059559(21)900004 (01)00884838059559(21)900005 (01)00884…
- FDA Device
- Class II
- terminated
- Published 2018-07-25
On 2018-07-25 the FDA classified a Class II recall of Ingenuity Digital PET/CT System, Model 882446 with the following UDI's: (01)00884838059559(21)900004 (01)00884838059559(21)900005 (01)00884… by Philips Medical Systems Cleveland, citing the block used to connect the patient pallet to the couch may be assembled incorrectly. A screw may be misaligned in the patient pallet.
Read the official FDA Device notice
| Agency | FDA Device |
|---|---|
| Recall number | Z-2496-2018 |
| Classification | Class II |
| Status | terminated |
| Initiated | 2018-05-21 |
| Published | 2018-07-25 |
| Last updated | 2026-09-13 11:54 UTC |
| Company | Philips Medical Systems Cleveland |
| Distribution | US |
Product
Ingenuity Digital PET/CT System, Model 882446 with the following UDI's: (01)00884838059559(21)900004 (01)00884838059559(21)900005 (01)00884838059559(21)900006 (01)00884838059559(21)900007 (01)00884838059559(21)900008 (01)00884838059559(21)900009 (01)00884838059559(21)900010 (01)00884838059559(21)900011 (01)00884838059559(21)900012 (01)00884838059559(21)900013 (01)00884838059559(21)900014 (01)00884838059559(21)900015 (01)00884838059559(21)900016 (01)00884838059559(21)900017 (01)00884838059559(21)900018 (01)00884838059559(21)900019 (01)00884838059559(21)900020 (01)00884838059559(21)900021 (01)00884838059559(21)900022 (01)00884838059559(21)900023 (01)00884838059559(21)900024 (01)00884838059559(21)900025 (01)00884838059559(21)900026 (01)00884838059559(21)900027 (01)00884838059559(21)900028 (01)00884838059559(21)900029 (01)00884838059559(21)900030 (01)00884838059559(21)900031 (01)00884838059559(21)900032 (01)00884838059559(21)900033 (01)00884838059559(21)900034 (01)00884838059559(21)900035 Product Usage: The system is intended to image the whole body, heart, brain, lung, gastrointestinal, bone, lymphatic, and other major organs for a wide range of patient types, sizes, and extent of diseases. Both subsystems can also be operated as fully functional, independent diagnostic tools, including application of the CT scanner for diagnosis and for use in radiation therapy planning.
Reason
The block used to connect the patient pallet to the couch may be assembled incorrectly. A screw may be misaligned in the patient pallet.
Identifiers
| code_info | Serial Numbers: 900004 900005 900006 900007 900008 900009 900010 900011 900012 900013 900014 900015 900016…Serial Numbers: 900004 900005 900006 900007 900008 900009 900010 900011 900012 900013 900014 900015 900016 900017 900018 900019 900020 900021 900022 900023 900024 900025 900026 900027 900028 900029 900030 900031 900032 900033 900034 900035 |
|---|
Status history
No status changes recorded since RecallRadar first saw this recall on 2026-09-13 11:54 UTC. Current status: terminated.
Other recalls by Philips Medical Systems Cleveland
- Pinnacle Radiation Therapy Planning System: Multimodality Simulation Workspace 18.0.5 Model 870258 UDI code: (01)00884838103566(10)18.0.5.2…
FDA Device · Class II · 2025-09-24 · Philips Medical Systems Cleveland - Pinnacle 3 with TumorLOC, (870258) Radiation Therapy Planning System Software
FDA Device · Class II · 2025-08-13 · Philips Medical Systems Cleveland - Pinnacle3 Radiation Therapy Planning System, Model numbers 870231 and 870237
FDA Device · Class II · 2022-09-21 · Philips Medical Systems Cleveland - Forte Gamma Camera System is intended to produce images depicting the anatomical distribution of single-photon and positron-emitting radioi…
FDA Device · Class I · 2019-11-13 · Philips Medical Systems Cleveland - Forte Gamma Camera System is intended to produce images depicting the anatomical distribution of single-photon and positron-emitting radioi…
FDA Device · Class I · 2019-11-13 · Philips Medical Systems Cleveland
All Philips Medical Systems Cleveland recalls
Source
Official record: https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-2496-2018%22
RecallRadar indexes public recall notices from the FDA, USDA FSIS, and CPSC. The official agency notice is the authoritative source. Always confirm details at the linked source before acting.