FDA Device recall Z-1439-2020
bellavista 1000 ventilator, Catalog number 301.100.030. bellavista is an electronically controlled pneumatic ventilation system with an int…
- FDA Device
- Class II
- terminated
- Published 2020-03-11
On 2020-03-11 the FDA classified a Class II recall of bellavista 1000 ventilator, Catalog number 301.100.030. bellavista is an electronically controlled pneumatic ventilation system with an int… by Vyaire Medical, citing the G6 bellavista 1000 US ventilators may experience intermittent failures: Lack of acoustic high priority alarm, presence of a 'no alarm' condition, or presence of non-responsive….
Read the official FDA Device notice
| Agency | FDA Device |
|---|---|
| Recall number | Z-1439-2020 |
| Classification | Class II |
| Status | terminated |
| Initiated | 2019-11-25 |
| Published | 2020-03-11 |
| Last updated | 2026-09-13 11:55 UTC |
| Company | Vyaire Medical |
| Distribution | US |
Product
bellavista 1000 ventilator, Catalog number 301.100.030. bellavista is an electronically controlled pneumatic ventilation system with an integrated air compressing system. bellavista uses room air and high-pressure oxygen. Air enters through a fresh gas intake port and is compressed together with the oxygen by the blower. Oxygen enters through a high pressure inlet. An electronic mixer valve provides for the operator-set concentration. Gas is supplied to the patient via the microprocessor controlled inspiratory valve.
Reason
The G6 bellavista 1000 US ventilators may experience intermittent failures: Lack of acoustic high priority alarm, presence of a 'no alarm' condition, or presence of non-responsive touch screen.
Identifiers
| code_info | Serial numbers: MB170104, MB170118, MB170151, MB170202, MB230000, MB230020, MB230024, MB230027, MB230031, MB230033, MB…Serial numbers: MB170104, MB170118, MB170151, MB170202, MB230000, MB230020, MB230024, MB230027, MB230031, MB230033, MB230035, MB230036, MB230037, MB230038, MB230039, MB230040, MB230041, MB230046, MB230048, MB230049, MB230052, MB230053, MB230054, MB230055, MB230056, MB230057, MB230058, MB230059, MB230060, MB230061, MB230062, MB230063, MB230064, MB230065, MB230066, MB230067, MB230068, MB230069, MB230070, MB230071, MB230072, MB230073, MB230074, MB230075, MB230076, MB230077, MB230078, MB230079, MB230080, MB230081, MB230082, MB230083, MB230084, MB230085, MB230086, MB230087, MB230088, MB230089, MB230090, MB230091, MB230092, MB230093, MB230094, MB230095, MB230097, MB230098, MB230099, MB230100, MB230101, MB230102, MB230104, MB230190, MB230191, MB230194, MB230195, MB230196, MB230197, MB230201, MB230204, MB230205, MB230207, MB230209, MB230210, MB230217, MB230219, MB230220, MB230221, MB230222, MB230227, MB230228, MB230229, MB230230, MB230231, MB230232, MB230233, MB230243, MB230244, MB230246, MB2 |
|---|
Status history
No status changes recorded since RecallRadar first saw this recall on 2026-09-13 11:55 UTC. Current status: terminated.
Source
Official record: https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-1439-2020%22