FDA Device recall Z-1055-2023

GE Nuclear Medicine 600/800 series systems, specifically: a) BRIVO B615 3/8 inch DHP BJG NR, b) BRIVO 615 3/8 inch, c) BRIVO B615 3/8 inch…

On 2023-02-15 the FDA classified a Class I recall of GE Nuclear Medicine 600/800 series systems, specifically: a) BRIVO B615 3/8 inch DHP BJG NR, b) BRIVO 615 3/8 inch, c) BRIVO B615 3/8 inch… by Ge Medical Systems Israel Functional Imaging, citing A mitigation may not be correctly implemented. If this is the case, the detector can fall, leading to life-threatening bodily injury.

Read the official FDA Device notice

AgencyFDA Device
Recall numberZ-1055-2023
ClassificationClass I
Statusongoing
Initiated2022-12-19
Published2023-02-15
Last updated2026-09-13 11:56 UTC
CompanyGe Medical Systems Israel Functional Imaging
DistributionUS

Product

GE Nuclear Medicine 600/800 series systems, specifically: a) BRIVO B615 3/8 inch DHP BJG NR, b) BRIVO 615 3/8 inch, c) BRIVO B615 3/8 inch DHP BJG NR, d) B615 with new rotor, e) BRIVO B615 3/8 inch BJG, f) BRIVO B615 3/8 inch DHP BJG NR, g) B615 with new rotor; Emission Computed Tomography System

Reason

A mitigation may not be correctly implemented. If this is the case, the detector can fall, leading to life-threatening bodily injury.

Identifiers

code_info
a) BRIVO B615 3/8 inch DHP BJG NR: Catalog number 5376204-16, UDI/DI Not Applicable, Serial Numbers: NT2QG1900001BH;…a) BRIVO B615 3/8 inch DHP BJG NR: Catalog number 5376204-16, UDI/DI Not Applicable, Serial Numbers: NT2QG1900001BH; b) BRIVO 615 3/8 inch: Catalog number 5376204-16, UDI/DI To be provided, Serial Numbers: NT2QG2000002BH; c) BRIVO B615 3/8 inch DHP BJG NR: Catalog number 5376204-16, UDI/DI Not Applicable, Serial Numbers: NT2QG2000001BH; d) B615 with new rotor: Catalog number 5376204-16, UDI/DI To be provided, Serial Numbers: NT2QG1900002BH; e) BRIVO B615 3/8 inch BJG: Catalog number 5376204-16, UDI/DI Not Applicable, Serial Numbers: NT2QG1800001BH; f) BRIVO B615 3/8 inch DHP BJG NR: Catalog number H2402MP, UDI/DI To be provided, Serial Numbers: 00000168527HL0; g) B615 with new rotor: Catalog number To be provided, UDI/DI Not Applicable, Serial Numbers: NT2QG2000003BH;