FDA Device recall Z-1052-2017
Carestream Touch Prime, Catalog # 1738830, and Touch Prime XE, Catalog # 1738822, Ultrasound System Diagnostic ultrasound imaging or fluid…
- FDA Device
- Class II
- terminated
- Published 2017-01-25
On 2017-01-25 the FDA classified a Class II recall of Carestream Touch Prime, Catalog # 1738830, and Touch Prime XE, Catalog # 1738822, Ultrasound System Diagnostic ultrasound imaging or fluid… by Carestream Health, citing software error; Carestream Health Inc, received a complaint stating that when a user accidentally obtains a measurement value of 0 and corrects the value in the report, the result….
Read the official FDA Device notice
| Agency | FDA Device |
|---|---|
| Recall number | Z-1052-2017 |
| Classification | Class II |
| Status | terminated |
| Initiated | 2016-11-21 |
| Published | 2017-01-25 |
| Last updated | 2026-09-13 11:54 UTC |
| Company | Carestream Health |
| Distribution | GA, IA, NY, OH, SC, TX |
Product
Carestream Touch Prime, Catalog # 1738830, and Touch Prime XE, Catalog # 1738822, Ultrasound System Diagnostic ultrasound imaging or fluid flow analysis of the human body
Reason
Software error; Carestream Health Inc, received a complaint stating that when a user accidentally obtains a measurement value of 0 and corrects the value in the report, the resulting measurement unit is not displayed, i.e., centimeters or millimeters. As such, the user expects that the measurement is taken calculated in centimeters, consistent with other values in the report. In actuality, the measurement is taken in millimeters. When this updated measurement is used in an average calculation, the result appears incorrect as two measurements are interpreted as centimeters while the user corrected value is interpreted as millimeters. If the user selects a Calc Result display as Min or Max, the values are also interpreted as millimeters when centimeters were expected.
Identifiers
| code_info | Serial Numbers: US units: 106, 112, 114, 116, 1021, 1037, 1038, 1044, 1057, 1067, 1072, 1074, 1079, 1090; OUS units: 10…Serial Numbers: US units: 106, 112, 114, 116, 1021, 1037, 1038, 1044, 1057, 1067, 1072, 1074, 1079, 1090; OUS units: 1005, 1006, 1009, 1011, 1015, 1017, 1018, 1020, 1031, 1041, 1042, 1043, 1045, 1081, 1086, 1089. |
|---|
Status history
No status changes recorded since RecallRadar first saw this recall on 2026-09-13 11:54 UTC. Current status: terminated.
Other recalls by Carestream Health
- DRX Revolution Mobile X-Ray System
FDA Device · Class II · 2023-12-13 · Carestream Health - The DRX-Revolution Mobile X-Ray System is a diagnostic mobile x-ray system utilizing digital radiography (DR) technology. the system consis…
FDA Device · Class II · 2023-11-15 · Carestream Health - DRX-Compass/DR-FIT X-ray Systems with Firmware version 2.3.2.0/2.3.2.4. For use in obtaining diagnostic quality radiographic images to aid…
FDA Device · Class II · 2023-03-08 · Carestream Health - Kodak DirectView DR3000/3500 - Product Usage: permanently installed as a diagnostic system intended to generate and control x-rays for exam…
FDA Device · Class II · 2020-01-22 · Carestream Health - OnSight 3D Extremity System- X-Ray, Tomography Computed System Catalog Numbers: 1743566 (w/ Attached Console) 1743574 (w/ Remote Console) T…
FDA Device · Class II · 2019-05-01 · Carestream Health
Source
Official record: https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-1052-2017%22