FDA Device recall Z-0874-2015
Solitaire-C Cervical Spacer System a) 14-531593 Drill/Awl Sleeve b) 14-531594 Spring-Loaded Drill/Awl Sleeve Intended to stabilize cervical…
- FDA Device
- Class II
- terminated
- Published 2014-12-31
On 2014-12-31 the FDA classified a Class II recall of Solitaire-C Cervical Spacer System a) 14-531593 Drill/Awl Sleeve b) 14-531594 Spring-Loaded Drill/Awl Sleeve Intended to stabilize cervical… by Ebi, citing A design deficiency was discovered whereby the Drill/Awl Sleeve and Spring-Loaded Drill/Awl Sleeve instruments (the Sleeves) allow the mating Drill and Awl instruments to penetr….
Read the official FDA Device notice
| Agency | FDA Device |
|---|---|
| Recall number | Z-0874-2015 |
| Classification | Class II |
| Status | terminated |
| Initiated | 2014-11-11 |
| Published | 2014-12-31 |
| Last updated | 2026-09-13 11:53 UTC |
| Company | Ebi |
| Distribution | US |
Product
Solitaire-C Cervical Spacer System a) 14-531593 Drill/Awl Sleeve b) 14-531594 Spring-Loaded Drill/Awl Sleeve Intended to stabilize cervical spinal segment to promote fusion in order to restrict motion and decrease pain using bone graft with or without supplemental fixation.
Reason
A design deficiency was discovered whereby the Drill/Awl Sleeve and Spring-Loaded Drill/Awl Sleeve instruments (the Sleeves) allow the mating Drill and Awl instruments to penetrate 1.0 mm beyond their intended depths during screw hole preparation.
Identifiers
| code_info | Part number 14-531593 Part number 14-531594 Catalog number Lot Number 14-531593 N23597 14-531594 N23599 |
|---|
Status history
No status changes recorded since RecallRadar first saw this recall on 2026-09-13 11:53 UTC. Current status: terminated.
Other recalls by Ebi
- Biomet SpinalPak Non-invasive Spine Fusion Stimulator System- Indicated for the treatment of an established nonunion acquired secondary to…
FDA Device · Class II · 2024-05-01 · Ebi - Biomet OrthoPak Non-invasive Bone Growth Stimulator System-Indicated for the treatment of an established nonunion acquired secondary to tra…
FDA Device · Class II · 2024-05-01 · Ebi - 20" Lead Wires, Replacement Part Number: 1067724-2
FDA Device · Class II · 2024-05-01 · Ebi - 48" Lead Wires, Replacement Part Number: 1067724-4
FDA Device · Class II · 2024-05-01 · Ebi - Cypher MIS Screw System-The system includes screws, various types and sizes of rods, and set screws
FDA Device · Class II · 2015-01-14 · Ebi
Source
Official record: https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-0874-2015%22
RecallRadar indexes public recall notices from the FDA, USDA FSIS, and CPSC. The official agency notice is the authoritative source. Always confirm details at the linked source before acting.