FDA Device recall Z-0662-2018
Fuji Computed Radiography Mammography Suite, FCRMS (for CR-IR363AWS) The Fuji Computed Radiography Mammography Suite (FCRMS) is a software…
- FDA Device
- Class II
- terminated
- Published 2018-02-28
On 2018-02-28 the FDA classified a Class II recall of Fuji Computed Radiography Mammography Suite, FCRMS (for CR-IR363AWS) The Fuji Computed Radiography Mammography Suite (FCRMS) is a software… by Fujifilm Medical Systems U, citing FUJIFILM Medical Systems U.S.A., Inc. (FMSU) identified a potential failure with our Mammography system. The acquisition workstations, FDR¿1000AWS, FDR-2000AWS, FDR-3000AWS, and C….
Read the official FDA Device notice
| Agency | FDA Device |
|---|---|
| Recall number | Z-0662-2018 |
| Classification | Class II |
| Status | terminated |
| Initiated | 2017-08-04 |
| Published | 2018-02-28 |
| Last updated | 2026-09-13 11:54 UTC |
| Company | Fujifilm Medical Systems U |
| Distribution | n/a |
Product
Fuji Computed Radiography Mammography Suite, FCRMS (for CR-IR363AWS) The Fuji Computed Radiography Mammography Suite (FCRMS) is a software device that, in conjunction with a specified Fuji Computed Radiography system forms the Fuji Computed Radiography for mammography (FCRm) device. FCRm with a dedicated mammographic x-ray machine generates digital mammographic images that can be used for screening and diagnosis of breast cancer. It is intended for use in the same clinical applications as traditional screen-film based mammographic (SFM) systems. The mammographic images can be interpreted by a qualified physician using either hardcopy film or softcopy display at a workstation.
Reason
FUJIFILM Medical Systems U.S.A., Inc. (FMSU) identified a potential failure with our Mammography system. The acquisition workstations, FDR¿1000AWS, FDR-2000AWS, FDR-3000AWS, and CR¿IR363AWS assign a unique ID number to every image study but very rarely, with the acquisition workstation software versions, VS.O, VS.1, VS.2 , V6.0, V6.1, and V7.0, the system may assign the same ID number to a new set of images that was already assigned to the previous set of images due to the error in ID number generation logic. If an Image with this error (with duplicate ID number) Is transmitted to PACS, it may overwrite the image already stored on PACS.
Identifiers
| code_info | 363AWS. Released Software Versions: V5.1, V6.0. Not Released Software Versions: V5.0, V5.2, V6.1, V7.0. |
|---|
Status history
No status changes recorded since RecallRadar first saw this recall on 2026-09-13 11:54 UTC. Current status: terminated.
Other recalls by Fujifilm Medical Systems U
- Synapse Cardiovascular (Synapse CV). Software Versions: 6.0 to 6.2.1 The Synapse Cardiovascular image is a management and reporting system
FDA Device · Class II · 2021-06-09 · Fujifilm Medical Systems U - ¿TASWako Chip Cassette is part of the Wako ¿TASWako i30 kit
FDA Device · Class II · 2021-04-21 · Fujifilm Medical Systems U - Synapse PACS - Radiological Image Processing System - Product Usage: intended for use, as a web based application, on an off-the-shelf PC m…
FDA Device · Class II · 2021-04-14 · Fujifilm Medical Systems U - FUJIFILM Synapse PACS Software: versions 7.0.0 and 7.0.1 - Product Usage: intended for use as a web based application on an off-the shelf P…
FDA Device · Class II · 2021-02-03 · Fujifilm Medical Systems U - Wako HDL-C/LDL-C Calibrator - Product Usage: designed to be used with Wako L-Type HDL-C or L-Type LDL-C for the determination of high densi…
FDA Device · Class III · 2021-02-03 · Fujifilm Medical Systems U
All Fujifilm Medical Systems U recalls
Source
Official record: https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-0662-2018%22
RecallRadar indexes public recall notices from the FDA, USDA FSIS, and CPSC. The official agency notice is the authoritative source. Always confirm details at the linked source before acting.