FDA Device recall Z-0379-2018
Metrotom 800 (130kV CT scanner) Industrial CT scanner for measuring and inspecting complete components made of plastic or light metal
- FDA Device
- Class II
- ongoing
- Published 2018-02-07
On 2018-02-07 the FDA classified a Class II recall of Metrotom 800 (130kV CT scanner) Industrial CT scanner for measuring and inspecting complete components made of plastic or light metal by Carl Zeiss Metrology, citing due to a software error, it was observed that when the user closes the access door, the system will resume its scan cycle automatically, instead of the user initiating x-ray gener….
Read the official FDA Device notice
| Agency | FDA Device |
|---|---|
| Recall number | Z-0379-2018 |
| Classification | Class II |
| Status | ongoing |
| Initiated | 2017-11-14 |
| Published | 2018-02-07 |
| Last updated | 2026-09-13 11:54 UTC |
| Company | Carl Zeiss Metrology |
| Distribution | AZ, CA, FL, GA, IL, NC, NJ, PR, WI |
Product
Metrotom 800 (130kV CT scanner) Industrial CT scanner for measuring and inspecting complete components made of plastic or light metal.
Reason
Due to a software error, it was observed that when the user closes the access door, the system will resume its scan cycle automatically, instead of the user initiating x-ray generation from the control panel.
Identifiers
| code_info | Serial Numbers: 152806 157499 157683 181193 181364 182887 186654 186767 186797 192099 192182 192351 197342 |
|---|
Status history
No status changes recorded since RecallRadar first saw this recall on 2026-09-13 11:54 UTC. Current status: ongoing.
Source
Official record: https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-0379-2018%22