RecallRadar

FDA Device recall Z-0084-2027

DxC 500 AU Clinical Chemistry Analyzers: 1. AU w/out ISE, Part No. C63519 2. AU w/ISE, Part No. C63520

On 2026-10-14 the FDA classified a Class II recall of DxC 500 AU Clinical Chemistry Analyzers: 1. AU w/out ISE, Part No. C63519 2. AU w/ISE, Part No. C63520 by Beckman Coulter, citing beckman Coulter has identified a software issue affecting DxC 500 AU Clinical Analyzers when testing plasma samples. Following user configuration of a Clinical Chemistry test to u….

Read the official FDA Device notice

AgencyFDA Device
Recall numberZ-0084-2027
ClassificationClass II
Statusongoing
Initiated2026-09-02
Published2026-10-14
Last updated2026-10-21 05:30 UTC
CompanyBeckman Coulter
DistributionUS

Product

DxC 500 AU Clinical Chemistry Analyzers: 1. AU w/out ISE, Part No. C63519 2. AU w/ISE, Part No. C63520

Reason

Beckman Coulter has identified a software issue affecting DxC 500 AU Clinical Analyzers when testing plasma samples. Following user configuration of a Clinical Chemistry test to use units different from the system default, a subsequent configuration change and activation of the draft configuration in the System Configuration page may cause the analyzer to revert the test units to the system default setting without notifying the user. The system does Pre-Review Reminders Include OII and [email protected] in any discussions on change/elevation of recalls to Class I classification and situations involving additional public communications (FDA and/or firm issued). Post-Review Reminders Final Check: Ensure your documentation accurately reflects the final recommendation prior to signature. Complete CTS: Recall Product tab, Additional Recall Event Info, Regulation, and Act. Upload PDFs of Consult, Review Memo, and Classification Letter for Class I Recall in DocMan. [Click to enter extra reminder]To add reminders, type the reminder in the text field to the left then press the Tab key. Doc ID 03534.05.06 2 of 8 not provide a warning or notification to alert the user that the configured units have reverted to the default units. This issue can result in falsely elevated reported results.

Identifiers

code_infoSoftware version 1.4.5 or earlier. 1. UDI-DI 14987666545058 2. UDI-DI 14987666545065

Status history

No status changes recorded since RecallRadar first saw this recall on 2026-10-21 05:30 UTC. Current status: ongoing.

Other recalls by Beckman Coulter

All Beckman Coulter recalls

Source

Official record: https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-0084-2027%22

RecallRadar indexes public recall notices from the FDA, USDA FSIS, and CPSC. The official agency notice is the authoritative source. Always confirm details at the linked source before acting.