FDA Device recall Z-0068-2018
Delta Cup Beater Positioner - Aligner, model # 9057.20.555 Used during implantation of the Delta Acetabular System
- FDA Device
- Class II
- completed
- Published 2017-11-15
On 2017-11-15 the FDA classified a Class II recall of Delta Cup Beater Positioner - Aligner, model # 9057.20.555 Used during implantation of the Delta Acetabular System by Limacorporate S P A, citing an internal analysis on complaints received indicated that the welding process may have been performed sub optimally in the 12 lot # involved , leading to reduced mechanical stren….
Read the official FDA Device notice
| Agency | FDA Device |
|---|---|
| Recall number | Z-0068-2018 |
| Classification | Class II |
| Status | completed |
| Initiated | 2017-09-08 |
| Published | 2017-11-15 |
| Last updated | 2026-09-13 11:54 UTC |
| Company | Limacorporate S P A |
| Distribution | n/a |
Product
Delta Cup Beater Positioner - Aligner, model # 9057.20.555 Used during implantation of the Delta Acetabular System
Reason
An internal analysis on complaints received indicated that the welding process may have been performed sub optimally in the 12 lot # involved , leading to reduced mechanical strength of the device and possible breakage during impaction when the instrument is subjected to repeated multi-axial stresses.
Identifiers
| code_info | Lot # 15AG0HJ, 15AG0HQ, 15AG0UY, 15AG00P, 15AG040, 15AG08Y, 14AG243, 15AG00Q, 15AG0UZ, 15AG0V0, 15AG0HN, 16AG02J |
|---|
Status history
No status changes recorded since RecallRadar first saw this recall on 2026-09-13 11:54 UTC. Current status: completed.
Source
Official record: https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-0068-2018%22
RecallRadar indexes public recall notices from the FDA, USDA FSIS, and CPSC. The official agency notice is the authoritative source. Always confirm details at the linked source before acting.