L.P. Gas Equipment gas leak detector fluid

On 2015-02-03 the CPSC announced a recall of L.P. Gas Equipment gas leak detector fluid by Fremont, citing explosion/Projectiles Fire & Fire-Related Burn.

Read the official CPSC notice

AgencyCPSC
Recall number75005
ClassificationNot classified
Statusunknown
Initiated1975-01-06
Published2015-02-03
Last updated2026-09-13 11:58 UTC
CompanyFremont
DistributionUS

Product

L.P. Gas Equipment gas leak detector fluid | Gas Leak Detector Fluid Warning NEWS from CPSC U.S. Consumer Product Safety Commission Office of Information and Public Affairs Washington, DC 20207 FOR IMMEDIATE RELEASE January 6, 1975 Release # 75-005 CPSC Warns Public Of Fire/Explosion Hazard Associated With Suspect Gas Leak Detector Fluid Washington, D.C. --The U.S. Consumer Product Safety Commission today warned consumers, mobile home manufacturers and distributors, and gas companies in Minnesota, Wisconsin, Iowa, Nebraska, North and South Dakota that a blue colored gas leak detector fluid distributed since 1972 by L.P. Gas Equipment, Inc., St. Paul, Minnesota, can corrode brass fittings and lead to hazardous gas leaks and subsequent fires and explosions. Any person or company that has used this detector fluid on brass connectors should have the piping inspected immediately for corrosion or discoloration. The connectors should be replaced as quickly as possible. Consumers in these states who have had gas appliances installed or inspected for leaks since 1972 should contact the company that installed the product or their local gas company for an immediate inspection. The corrosion problem apparently is due to the presence of ammonia in the fluid. A common method of installing gas appliances is to use a flexible brass connector to connect the appliance to rigid piping. If a leak detector fluid containing ammonia is used to check for faulty tube fittings, the ammonia residue can cause cracks and leaks in the brass. These cracks can enlarge over time. The fluid was manufactured by Fremont Industries, Shakopee, Minnesota, for L. P. Gas Equipment, Inc., which sold 1,155 gallons of the solution, in various package sizes, to 117 gas companies. L. P. Gas has asked its purchasers-- none of whom would be consumers -- to discontinue use of the fluid and to destroy existing stocks. The Commission obtained the names of these customers by subpoena and is advising them of the serious nature of the hazard. The Commission also is encouraging immediate inspection and replacement of all fittings that may have been treated with the suspect leak detector fluid. At the same time, the Commission is proceeding with administrative action that could lead to mandatory corrective action by the manufacturer, distributors and retailers of the fluid. The State of Minnesota, Building Code Division, reported the potential problem of the ammonia containing fluid to the Commission's Minneapolis Area Office in September 1974. The Commission consulted with the National Bureau of Standards in order to confirm that the corrosion damage was, or could have been, caused by the ammonia solution. This warning is being issued in the interest of the public health and safety.

Reason

Explosion/Projectiles Fire & Fire-Related Burn

Status history

No status changes recorded since RecallRadar first saw this recall on 2026-09-13 11:58 UTC. Current status: unknown.

Source

Official record: https://www.cpsc.gov/Recalls/1975/CPSC-Warns-Public-Of-FireExplosion-Hazard-Associated-With-Suspect-Gas-Leak-Detector-Fluid

RecallRadar indexes public recall notices from the FDA, USDA FSIS, and CPSC. The official agency notice is the authoritative source. Always confirm details at the linked source before acting.