CPSC recall 05511
Rotating Cross Bar SCUBA Manifold
- CPSC
- unknown
- Published 2024-11-14
On 2024-11-14 the CPSC announced a recall of Rotating Cross Bar SCUBA Manifold by Ocean Management Systems, citing undersized o-rings installed on the cross bar can cause a loss of breathing air from the SCUBA cylinder, presenting a risk of drowning.
| Agency | CPSC |
|---|---|
| Recall number | 05511 |
| Classification | Not classified |
| Status | unknown |
| Initiated | 2004-11-17 |
| Published | 2024-11-14 |
| Last updated | 2026-09-13 11:58 UTC |
| Company | Ocean Management Systems |
| Distribution | US |
Product
Rotating Cross Bar SCUBA Manifold | The recall involves the 200 and 300 Bar versions of the OMS Rotating Cross Bar Manifold. The manifold consists of two valves which have "O.M.S." stamped on the side of each valve and a crossbar that has three O-rings per side. Each part has a black plastic knob.
Reason
Undersized o-rings installed on the cross bar can cause a loss of breathing air from the SCUBA cylinder, presenting a risk of drowning.
Status history
No status changes recorded since RecallRadar first saw this recall on 2026-09-13 11:58 UTC. Current status: unknown.
Source
Official record: https://www.cpsc.gov/Recalls/2005/CPSC-Ocean-Management-Systems-Announce-Recall-of-SCUBA-Manifolds-